The MoveoSiphon ST24 is a CE-certified disinfection system for sink drains in clinical, sanitary areas. Its continuous and fully automatic disinfection process prevents the production of infectious bio-aerosols and thus the transfer of pathogens from the washbasin to the patient. In the process the following functional processes interact:
- Continuous physical-thermal disinfection
- Electromechanical vibration cleaning of the inside walls of the siphon
Good reasons for using the MoveoSiphon ST24
Features
Features
The MoveoSiphon ST24 provides effective outbreak protection. It continuously and completely cleans and disinfects the trap liquid in the odour trap under the sink automatically. The trapped liquid is disinfected by means of thermal disinfection whilst the vibration cleaning prevents biofilm formation. Thus, the odour trap is permanently excluded from being a pathogen reservoir and source of outbreaks.
The MoveoSiphon operating function
DISINFECTION
The thermo disinfection carried out by the MoveoSiphon fulfils the technical process of pasteurization by means of heating (10 to 15 seconds at 85°C), and slowly cools down while the subsequent vibration cleaning takes place
CLEANING
The unit heats up to the set temperature (85°C) and slowly cools down to minimum set temperature (75°C). Once it reaches 75°C , the heating process and thus the disinfection cleaning cycle recommence again
STANDBY
If no interruption is caused by additional water inflow, then the entire process is completed after 5-6 cycles in a period of approximately one hour and the MoveoSiphon switches into standby mode until water flows in again
The MoveoSiphon operating function
DISINFECTION
The thermo disinfection carried out by the MoveoSiphon fulfils the technical process of pasteurization by means of heating (10 to 15 seconds at 85°C), and slowly cools down while the subsequent vibration cleaning takes place
CLEANING
The unit heats up to the set temperature (85°C) and slowly cools down to minimum set temperature (75°C). Once it reaches 75°C , the heating process and thus the disinfection cleaning cycle recommence again
STANDBY
If no interruption is caused by additional water inflow, then the entire process is completed after 5-6 cycles in a period of approximately one hour and the MoveoSiphon switches into standby mode until water flows in again
Sources
1) Hygiene Nord GmbH/Greifswald, Prüfbericht A 13228, 17.12.2013; 2) Sissoko und Sütterlin (2004), Vortrag 7. internationaler Kongress der Deutschen Gesellschaft für Krankenhaushygiene DGKH, Berlin; 3) Monatsschrift Kinderheilkunde 2013 (Suppl 2) DGKJ-PO-12-11
"*" indicates required fields